| Product Name: | Multi-parameter Monitor |
| Description: | WESTINGAREA supplied M350619 Multi-parameter Monitor have the excellent performance
displayed as:
Features
* Color TFT Screen, waveform up to 8 channels ;
* Light and portable with build-in rechargeable battery ;
* UP to 10 kinds of monitor parameters ;
* Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis ;
* 72 hour storage and review of trend grams and tables, 40 second review
of olographic wavefo rms;
* Built-in recorder(option) ;
* All-round monitor of adult ,pediatric and neonatal. ;
* Electrosurgical unit and defibrillation protected ;
* Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature,
Pulse rate;
* Option parameters: EtCO2, CO, IBP, Thermal ;Printer
ECG
* 5-lead or 3-lead selectable ;
* Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C ;
* Lead selection: I; II; III; avR; avL; avF; Vx; CAL ;
* Gain selection: 12.5mm/s, 25mm/s, 50mm/s ;
* Accuracy: ?bpm or ?%, whichever is greater ;
* Protection: Withstand 4000VAC/50Hz voltage in isolation against;
electrosurgical and defibrillation ;
* Calibration signal: 1mV?% ;
* Operation modes: Diagnostic, Monitor, Surgery ;
* Alarm range: Adult: 15-300bpm ;
* Pediatric/Neonatal: 15-350bpm ;
* Alarm range: -2.0mV~2.0mV ;
* S-T detection: YES, Arrhythmia analysis: YES ;
* Alarm: YES, audible and visual alarm, alarm events recallable ;
NIBP
* Method: Oscillometry ;
* Operation modes: Manual/Automatic/STAT ;
* Measurement unit: mmHg/KPa selectable ;
* Measurement types: Systolic, Diastolic, Mean ;
* Measurement range: Adult: 10-270mmHg ;
* Over-pressure protection: YES;
* Resolution: 1mmHg ;
* Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10;
* Alarm: Systolic,Diastolic,Mean;
SpO2
* Measurement range: 0-100% ;
* Accuracy: ?digit (70~100%);
* 0~69% unspecified ;
* Alarm range: 0-100% ;
Respiration
* Method: RA-LL impedance ;
* Pediatric/Neonatal: 6-150rpm ;
* Alarm range: Adult: 6-120rpm ;
* Pediatric/Neonatal: 6-150rpm ;
* Apnea alarm: YES ;
Temperature
* Resolution: 0.1¡æ;
* Channel: Dual-channel ;
* Alarm range: 0-50¡æ;
Option:
EtCO2
* Measurement Mode: Side-stream or mainstream;
* Measurement range: EtCO2: 0-99mmHg ;
* Accuracy: CO2 concentration ;
* Apnea alarm: YES ;
CO
* Method: Thermo-dilution;
* Measurement range: CO: 0.1-20 lit./min. ;
IBP
* Channel: 2 channels;
* Pressure transducer: Sensitivity: 5( mV/V/mmHg) ;
* Transducer sites: ART, PA, CVP, RAP, LAP, ICP ;
* Alarm range: -10~300mmHg ; |
| |
| Remarks: | Price will be negotiable if order quantity is big. Please do not hesitate to contact WESTINGAREA customer service engineer in your area, if you have any further question.
Multi-parameter Monitor-Patient Monitor, monitor, Pulse Oximeter, Oximeter, Pulse oximetry, meter ,WESTINGAREA Group supply Multi-parameter Monitor-Patient Monitor, monitor, Pulse Oximeter, Oximeter, Pulse oximetry, meter , high quality of Multi-parameter Monitor-Patient Monitor, monitor, Pulse Oximeter, Oximeter, Pulse oximetry, meter , being a high quality Multi-parameter Monitor-Patient Monitor, monitor, Pulse Oximeter, Oximeter, Pulse oximetry, meter supplier , we supply Multi-parameter Monitor-Patient Monitor, monitor, Pulse Oximeter, Oximeter, Pulse oximetry, meter all over the world.
|
|