Analog Oscilloscope

Analog Oscilloscope
Click to enlarge
Product Name: Analog Oscilloscope
Description: WESTINGAREA supplied L1011342 Analog Oscilloscope have the excellent
performance displayed as

Specification:

珨﹜Feature

* 20MHz Dual Channels

* High Sensitivity 1mV/DIV

* Z Axis Input

* CH1 Output

* 10 times sweep magnification

* TV Synchronization,X-Y mode

* High luminance,internal graticule Toshiba CRT

* Japanese electronic encoder,light,handy and reliable

* Fully sealed long live vertical mode swetch

* ALT Triggering Function,two independent signals

* Triggering level lock function. Automatic synchronize function

* Build-in 6 Digit Frequency Counter

媼﹜Technical specifications

1﹜Vertical System

Sensitivity 5mV~5V/div,10 steps in 1-2-5 sequence
Sensitivity Accuracy ≒3%(℅5 MAG: ≒5%)Vernier
vertical Sensitivity; Continuously variable to
1/2.5 or less of panel-indicated value Frequency

Bandwidth DC~20MHz(℅5 MAG:DC~7MHz) AC Coupling:
Low limit frequency 10Hz.(With reference to 100Kz,
8DIV. Frequency response with-3dB)

Rise Time Approx:17.5ns(℅5 MAG:50ns)

Input Impedance Approx:1M次/25pF

Square wave characteristics: Overshoot: ≒5%(At 10mV/div range)

Other distortions and other ranges:5% added to the above value.

DC Balance Shift 5mV~5V/div:㊣0.5DIV, 1mV~2Mv/DIV ㊣2.0DIV

Linearity ˉ㊣0.1DIV of amplitude change when
waveform of 2DIV at graticule center is moved vertically.

Vertical system: CH1: Channel 1
CH2: Channel2
DUAL: Channel 1 and Channel 2
ADD: Addition of Channel 1 and Channel 2

Chopping repetition Frequency Approx.. 250KHz

Input Coupling AC , GND , DC

Maxmum Input Voltage 300Vpeak(AC: frequency 1kHz or lower)

Common mode rejection ratio:50: 1 or better at 50KHz
sinusoidal wave(When sensitivities of CH1 and CH2 are set equally)

Isolation between channels(At 5mv/DIV range)
ˇ1000: 1 at 50kHz ; ˇ30: 1 at 20MHz

2﹜ Horizontal System

Sweep time: 0.2uSec~0.5Sec/DIV, 20steps in 1-2-5 sequence;

Sweep time accuracy: ㊣3%

Vernier sweep time control: ≒1/2.5 of panel-indicated value;

Sweep magnification: 10 times;

℅10MAG sweep time accuracy: ㊣5%(20nsec ~50nsec are uncalibrated)

Linearity: ㊣3%, ℅10MAG ㊣5%(20nsec ~50nsec are uncalibrated)

Position shift caused by ℅10MAG: within 2DIV. at CRT screen center

3﹜X-Y MODE

Sensitivity:5Vp-p(X-axis:CH1 input signal, Y-axis:CH2 input signal);

Frequency bandwidth: DC to atleast 500kHz;

X-Y phase difference: ≒30 at DC~5kHz

4﹜Z Axis

Sensibility: 5Vp-p (Positive-going signal decreases intensity)

Frequency bandwidth: DC~2MHz

Input resistance : Apporx. 47k次

Maximum input voltage: 3V (DC+AC peak, AC frequency ≒1kHz)

5﹜CALIBRATION VOLTAGE

Waveform: Positive-going square wave;

Frequency: Approx. 1kHz;

Duty ratio: Within 48: 52;

Output voltage: 2Vp-p ㊣2%; Output impedance: Approx. 1k次

6﹜CRT

Type: 6inch rectangular type, internal graticule;

Phosphor: P31

Acceleration voltage: Approx. 2kV

Effective screen size: 8℅10DIV(1 DIV=10mm(0.39in))

Graticule: Internal

Trace rotation: provided

7﹜TRIGGERING

Triggering source: CH1, CH2, LINE, EXT

Coupling: AC: 20Hz to full bandwidth

Slope: +/-

Sensitivity: 20Hz~2MHz: 1.0DIV

TRIG-ALT: 2DIV, EXT: 200mV

2~2MHz: 1.5DIV

TRIG-ALT: 3DIV, EXT: 800mV;

TV: Sync pulse more than 1DIV (EXT: 1V)

Triggering modes: AUTO; NORM; TV-V; TV-H; (Both TV-V and
TV-H synchronize only when the synchronizing signal is negative)

EXT triggering signal input:

Input impedance: Approx: 1M次/approx. 25p

Max. input voltage: 300V(DC+AC peak), AC:
Frequency not higher than 1kHz

7﹜Power requirement

Voltage: Fixed AC220V㊣10% or 110/220V㊣10% selectable

Frequency:50/60Hz

Power conseumption: Approx.40VA,35W(max)

8﹜Operating Ambient

Indoor,2000m elevation

Ambient temperature:10⊥~35⊥

Max operating range:0⊥~40⊥

Humidity:85% RH ,dry

Size:310℅150℅455(mm)

Weight:approx.8Kg

Storage temperature:-10⊥~70⊥

9﹜Accessories:

Power cord: ℅1; Instruction manual:℅1 ; Probs:℅2 ;
Remarks: Price will be negotiable if order quantity is big.
Please do not hesitate to contact WESTINGAREA customer service engineer in your area, if you have any further question.
Analog Oscilloscope-Oscilloscope, Analog Oscilloscope, General Oscilloscope, Digital Oscilloscope ,WESTINGAREA Group supply Analog Oscilloscope-Oscilloscope, Analog Oscilloscope, General Oscilloscope, Digital Oscilloscope , high quality of Analog Oscilloscope-Oscilloscope, Analog Oscilloscope, General Oscilloscope, Digital Oscilloscope , being a high quality Analog Oscilloscope-Oscilloscope, Analog Oscilloscope, General Oscilloscope, Digital Oscilloscope supplier , we supply Analog Oscilloscope-Oscilloscope, Analog Oscilloscope, General Oscilloscope, Digital Oscilloscope all over the world.
P/N List
P/N Description Unit Price(USD) Standard MOQ.
L1011342 Specification: 珨﹜Feature * 20MHz Dual Channels * High Sensitivity 1mV/DIV * Z Axis Input * CH1 Output * 10 times sweep magnification * TV Synchronization,X-Y mode * High luminance,internal graticule Toshiba CRT * Japanese electronic encoder,light,handy and reliable * Fully sealed long live vertical mode swetch * ALT Triggering Function,two independent signals * Triggering level lock function. Automatic synchronize function * Build-in 6 Digit Frequency Counter 媼﹜Technical specifications 1﹜Vertical System Sensitivity 5mV~5V/div,10 steps in 1-2-5 sequence Sensitivity Accuracy ≒3%(℅5 MAG: ≒5%)Vernier vertical Sensitivity; Continuously variable to 1/2.5 or less of panel-indicated value Frequency Bandwidth DC~20MHz(℅5 MAG:DC~7MHz) AC Coupling: Low limit frequency 10Hz.(With reference to 100Kz, 8DIV. Frequency response with-3dB) Rise Time Approx:17.5ns(℅5 MAG:50ns) Input Impedance Approx:1M次/25pF Square wave characteristics: Overshoot: ≒5%(At 10mV/div range) Other distortions and other ranges:5% added to the above value. DC Balance Shift 5mV~5V/div:㊣0.5DIV, 1mV~2Mv/DIV ㊣2.0DIV Linearity ˉ㊣0.1DIV of amplitude change when waveform of 2DIV at graticule center is moved vertically. Vertical system: CH1: Channel 1 CH2: Channel2 DUAL: Channel 1 and Channel 2 ADD: Addition of Channel 1 and Channel 2 Chopping repetition Frequency Approx.. 250KHz Input Coupling AC , GND , DC Maxmum Input Voltage 300Vpeak(AC: frequency 1kHz or lower) Common mode rejection ratio:50: 1 or better at 50KHz sinusoidal wave(When sensitivities of CH1 and CH2 are set equally) Isolation between channels(At 5mv/DIV range) ˇ1000: 1 at 50kHz ; ˇ30: 1 at 20MHz 2﹜ Horizontal System Sweep time: 0.2uSec~0.5Sec/DIV, 20steps in 1-2-5 sequence; Sweep time accuracy: ㊣3% Vernier sweep time control: ≒1/2.5 of panel-indicated value; Sweep magnification: 10 times; ℅10MAG sweep time accuracy: ㊣5%(20nsec ~50nsec are uncalibrated) Linearity: ㊣3%, ℅10MAG ㊣5%(20nsec ~50nsec are uncalibrated) Position shift caused by ℅10MAG: within 2DIV. at CRT screen center 3﹜X-Y MODE Sensitivity:5Vp-p(X-axis:CH1 input signal, Y-axis:CH2 input signal); Frequency bandwidth: DC to atleast 500kHz; X-Y phase difference: ≒30 at DC~5kHz 4﹜Z Axis Sensibility: 5Vp-p (Positive-going signal decreases intensity) Frequency bandwidth: DC~2MHz Input resistance : Apporx. 47k次 Maximum input voltage: 3V (DC+AC peak, AC frequency ≒1kHz) 5﹜CALIBRATION VOLTAGE Waveform: Positive-going square wave; Frequency: Approx. 1kHz; Duty ratio: Within 48: 52; Output voltage: 2Vp-p ㊣2%; Output impedance: Approx. 1k次 6﹜CRT Type: 6inch rectangular type, internal graticule; Phosphor: P31 Acceleration voltage: Approx. 2kV Effective screen size: 8℅10DIV(1 DIV=10mm(0.39in)) Graticule: Internal Trace rotation: provided 7﹜TRIGGERING Triggering source: CH1, CH2, LINE, EXT Coupling: AC: 20Hz to full bandwidth Slope: +/- Sensitivity: 20Hz~2MHz: 1.0DIV TRIG-ALT: 2DIV, EXT: 200mV 2~2MHz: 1.5DIV TRIG-ALT: 3DIV, EXT: 800mV; TV: Sync pulse more than 1DIV (EXT: 1V) Triggering modes: AUTO; NORM; TV-V; TV-H; (Both TV-V and TV-H synchronize only when the synchronizing signal is negative) EXT triggering signal input: Input impedance: Approx: 1M次/approx. 25p Max. input voltage: 300V(DC+AC peak), AC: Frequency not higher than 1kHz 7﹜Power requirement Voltage: Fixed AC220V㊣10% or 110/220V㊣10% selectable Frequency:50/60Hz Power conseumption: Approx.40VA,35W(max) 8﹜Operating Ambient Indoor,2000m elevation Ambient temperature:10⊥~35⊥ Max operating range:0⊥~40⊥ Humidity:85% RH ,dry Size:310℅150℅455(mm) Weight:approx.8Kg Storage temperature:-10⊥~70⊥ 9﹜Accessories: Power cord: ℅1; Instruction manual:℅1 ; Probs:℅2 ; 3C/CE/ROHS

RFQ
Related Products
Kickboxing Gloves Kickboxing Gloves Thin Bag Gloves Thin Bag Gloves
Thin Bag Gloves Thick Bag Gloves Velcro Training Glov... Lace-up Training Glo...
Outcrop Finger Bag G... Outcrop Finger Bag G... Thick Bag Gloves Thick Bag Gloves
Thick Bag Gloves Thick Bag Gloves Thick Bag Gloves Weight Bag Gloves(Ad...
Kickboxing Headgear Kickboxing Headgear Kickboxing Protector... Children's Velcro Ba...
Velcro Training Glov... Velcro Practing Glov... Lace-up Practing Glo... Elastic Practing Glo...
Elastic Practing Glo... Velcro Training Glov... Velcro Training Glov... Sea Scooter
Digital Oscilloscope Digital Storage Osci... Digital Storage Osci... Hot-air sterilizer
Digital Storage Osci... Slow Sweep Oscillosc... Dual Trace 20MHz Osc... Dual-Trace/Slow Swee...
20MHz Dual Trace Osc... 20MHz Dual Trace Osc... Dual-Trace Oscillosc... 20MHz Dual Trace Osc...
20MHz Dual-Trace Osc... Dual-Trace Oscillosc... 300MHz CRT Readout D... Dual-channel 60MHz O...
Dual-channel 40MHz O... Dual-channel 20MHz O... Dual-channel/Dual-Sw... Dual-channel 100MHz ...
100MHz CRT Readout O... 150MHz Dual Trace Os... Transistor Curve Tra... Digital Storage Osci...
Digital Storage Osci... Many Pipe Carriers A... Tabletop High Speed ... Tabletop High Speed ...
Tabletop High Speed ... Tabletop High Speed ... High Speed Refrigera... High Speed Refrigera...
High Speed Refrigera... High Speed Refrigera... Large Capacity Refri... Large Capacity Refri...
Low Speed Refrigerat... Low Speed Centrifuge Tabletop High Speed ... Tabletop High Speed ...
Tabletop High Speed ... Auto Groover Layout Blocker Pattern Maker
Lens Edger Lens Edger Digital Oscilloscope Digital Oscilloscope
Digital Oscilloscope Digital Oscilloscope Low Speed Centrifuge Low Speed Centrifuge
Digital Oscilloscope Digital Oscilloscope Digital Oscilloscope Digital Oscilloscope
Digital Oscilloscope Digital Oscilloscope Digital Oscilloscope Digital Oscilloscope
Digital Oscilloscope Capillary Blood Cent... Fillter Desk-toply C... Low Speed Many Pipe ...
Thermostatical Crude... Low Speed Centrifuge Low Speed Centrifuge Low Speed Centrifuge
Blood Washing Centri... High Speed Refrigera... High Speed Refrigera... High Speed Refrigera...

     Ehsy.com | Contact Us | Sitemap1 | Sitemap2 | flammable liquid storage cabinet | safety cabinets | safety goggle | dust mask | telescope
     safes | processing aid | impact modifiers

    Copyright © 2002-2006 Westingarea Corporation All Rights Reserved.Terms of Use | Privacy Statement