| P/N |
Description |
Unit Price(USD) |
Standard |
MOQ. |
| L1172240 |
* Temperature range(¡æ):-5¡«+90¡æ;
* Temperature stability(¡æ):¡À0.05;
* Display resolutions(¡æ):0.1/0.01;
* Digital setting(¡æ):0.01;
* Heater wattages(W):4,500;
* Cooling capacity @20¡æ ambient(W):
+20¡æ 2,000,0¡æ 1,500;
* Compressor size(W):1,100;
* Refrigerants: HFC404a/HFC22;
* Programming: 99segments¡Á99hr59min, 99 cycles;
* Interior size( mm):450W¡Á670D¡Á400H;
* Bath opening(mm):420W¡Á640D;
* Overall dimensions(mm);550W¡Á850D¡Á980H;
* Duty cycle:Continuous;
* Auxiliaries and safety functions:ATC,
temperature sensor failure cutoff and
alarm, high-temperature cutoff and low
temperature alarm, and run-dry cutoff;
* Power:AC220V¡À10%, 50Hz/AC380V¡À10%, 50Hz; |
|
ISO9001 |
|
| L1172241 |
* Temperature range(¡æ):-20¡«+90¡æ;
* Temperature stability(¡æ):¡À0.05;
* Display resolutions(¡æ):0.1/0.01;
* Digital setting(¡æ):0.01;
* Heater wattages(W):4,500;
* Cooling capacity @20¡æ ambient(W):
+20¡æ 2,500,0¡æ 2000,-20¡æ 500;
* Compressor size(W):750;
* Refrigerants: HFC404a/HFC22;
* Programming: 99segments¡Á99hr59min, 99 cycles;
* Interior size( mm):450W¡Á670D¡Á400H;
* Bath opening(mm):420W¡Á640D;
* Overall dimensions(mm);550W¡Á850D¡Á980H;
* Duty cycle:Continuous;
* Auxiliaries and safety functions:ATC,
temperature sensor failure cutoff and
alarm, high-temperature cutoff and low
temperature alarm, and run-dry cutoff;
* Power:AC220V¡À10%, 50Hz/AC380V¡À10%, 50Hz; |
|
ISO9001 |
|
| L1172242 |
* Temperature range(¡æ):-10¡«+90¡æ;
* Temperature stability(¡æ):¡À0.05;
* Display resolutions(¡æ):0.1/0.01;
* Digital setting(¡æ):0.01;
* Heater wattages(W):3,000;
* Cooling capacity @20¡æ ambient(W):
+20¡æ 2,000,0¡æ 1,500;
* Compressor size(W):1,100;
* Refrigerants: HFC404a/HFC22;
* Programming: 99segments¡Á99hr59min, 99 cycles;
* Interior size( mm):480W¡Á460D¡Á400H;
* Bath opening(mm):440W¡Á420D;
* Overall dimensions(mm);550W¡Á610D¡Á980H;
* Duty cycle:Continuous;
* Auxiliaries and safety functions:ATC,
temperature sensor failure cutoff and
alarm, high-temperature cutoff and low
temperature alarm, and run-dry cutoff;
* Power:AC220V¡À10%, 50Hz/AC380V¡À10%, 50Hz; |
|
ISO9001 |
|
| L |
* Temperature range(¡æ):-25¡«+90¡æ;
* Temperature stability(¡æ):¡À0.05;
* Display resolutions(¡æ):0.1/0.01;
* Digital setting(¡æ):0.01;
* Heater wattages(W):3,000;
* Cooling capacity @20¡æ ambient(W):
+20¡æ 2,500,0¡æ 2000,-20¡æ 500;
* Compressor size(W):750;
* Refrigerants: HFC404a/HFC22;
* Programming: 99segments¡Á99hr59min, 99 cycles;
* Interior size( mm):480W¡Á460D¡Á400H;
* Bath opening(mm):440W¡Á420D;
* Overall dimensions(mm);550W¡Á610D¡Á980H;
* Duty cycle:Continuous;
* Auxiliaries and safety functions:ATC,
temperature sensor failure cutoff and
alarm, high-temperature cutoff and low
temperature alarm, and run-dry cutoff;
* Power:AC220V¡À10%, 50Hz/AC380V¡À10%, 50Hz; |
|
|
|